Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Chinese Journal of Clinical Oncology ; (24): 217-221, 2015.
Article in Chinese | WPRIM | ID: wpr-672137

ABSTRACT

Objective:To analyze survival in patients with advanced oral cancer from prospective clinical trials. Methods:From 2008 to 2010, 256 patients with oral cancer at clinical stage III/IVA were randomly categorized into two groups. Patients in the experi-mental group received neo-adjuvant chemotherapy, surgery, and post-operative radiation, and patients in the control group underwent surgery and post-operative radiation. All patients were routinely followed-up after treatments. Survival was analyzed using Kaplan–Meier method and log-rank test, and differences were considered statistically significant at P value lower than 0.05. Results: Each group was composed of 128 patients. With the median follow-up period of 60 months, the 5-year overall survival rate was 61.7%and the disease-free survival rate was 53.9%. The overall survival rate (P=0.350) and the disease-free survival rate (P=0.160) were not sig-nificantly different between the experimental and control groups. Patients with positive pathological response to neo-adjuvant chemo-therapy exhibited significantly improved overall survival (P<0.05). Conclusion:Radical surgery should be emphasized to improve the prognosis of oral cancer. Functional reconstruction could also improve the quality of life and survival of patients. Despite that neo-adju-vant chemotherapy could not improve the survival of patients with advanced oral cancer in entirety, it could benefit patients exhibiting positive treatment responses.

2.
Chinese Journal of Tissue Engineering Research ; (53): 7624-7628, 2015.
Article in Chinese | WPRIM | ID: wpr-484958

ABSTRACT

BACKGROUND:Due to limitations of the physicochemical properties of soft denture liner material itself, whisker has been added in the soft lining material in recent years, so as to enhance its mechanical properties. OBJECTIVE:To investigate the effect of different additive amount of anhydrous calcium sulfate whisker on the mechanical function of self-curing soft denture liner. METHODS: There were six groups in this experiment. Anhydrous calcium sulfate whisker at the mass fraction of 0 (control), 1%, 2%, 3%, 4%, 5% was respectively added into self-curing soft liner materials, 10 test specimens in each group, a total of 60 test specimens. The shear bond strength, Shore hardness and tensile strength were detected. RESULTS AND CONCLUSION: With the increasing amount of the anhydrous calcium sulfate whisker, the Shore hardness of the soft lining material was increased continuously, and the tensile strength was increased firstly and then reduced. When 3% anhydrous calcium sulfate whisker was added, the bond strength and tensile strength of soft lining material reached the peak. Taken together, the mechanical properties of the soft lining materials became perfect when 3% anhydrous calcium sulfate whisker was added. These results demonstrate that anhydrous calcium sulfate whisker may affect the mechanical properties of self-curing soft liner.

3.
Chinese Journal of Physical Medicine and Rehabilitation ; (12): 417-421, 2011.
Article in Chinese | WPRIM | ID: wpr-415730

ABSTRACT

Objective To determine the power-time-ablation scope correlogram of a water-cooled single needle electrode radiofrequency (RF) ablation system and to establish a theoretical basis for its practical application.Methods RF ablations were performed using a water-cooled single needle electrode radiofrequency ablation system developed by the authors using fresh ox liver as well as liver and muscles of healthy adult New Zealand white rabbits.The temperature of the ablation area was monitored using a multichannel thermometric system.The maximum ablation scope was determined by detecting the rim at which the temperature was no less than 50 °C.The specific absorption rate (SAR) of the isolated liver tissue was calculated.Results In the treatment voltage range of 100-130V,the process was smooth and steady.No impedance variation was obvious.The maximum diameter of a single ablation was 51 cm.With the treatment voltage at 140-170 V,a larger ablation area could be reached in less time,but eventually the impedance began to increase while the ablation area was no longer expanded.When the treatment voltage reached the range of 180-200 V the impedance almost always increased rapidly out of limits,and the treatment system stopped automatically.The measured SAR value was consistent with the theoretical value.Pathology confirmed that both liver tissue and muscle tissue manifested typical coagulative necrosis.Conclusions The power amplifier,cooling,thermometric and control sections of the RF ablation system worked stably,and the practical ablation effect met the design and clinical treatment requirements.

SELECTION OF CITATIONS
SEARCH DETAIL